Most Granulators Flat Die Suppliers will tell you about these solutions the reason and treatment of main shaft wobble of granulator
1. The tail of the spindle is not tightened or tightened;
2. Large space between the spline and spline seat of the main shaft of models 350 and above, and large space between the keyway at the tail of the main shaft of models 32 and below.
3. Large gap between safety pin and safety pin sleeve, safety pin sleeve and safety pin holder;
4. Main shaft bearing flower bar deformation or bearing wear;
5. The diameter loss of inner hole of annulus mold is greater than or equal to 0.30;
6. Uneven adjustment of the gap between the two rollers;
We supply high quility Biomass Feed Pellet Roller Shell. If you have demand about our products, welcome to our website know more details.
Copyright © Zhangjiakou Hongxing Machinery Co., Ltd. All Rights Reserved